Data Sheet - iMOD096V055

Generate PDF

*Shown with optional CAN Monitoring Module

General

Part / Ordering Info:

iMOD096V055A23-01B Active Balancing, Digital OV, Analog Temperature

iMOD096V055A23-03B Active Balancing, CAN monitoring

iMOD096V055P23-01B Passive Balancing, Digital OV, Analog Temperature

iMOD096V055P23-03B Passive Balancing, CAN Monitoring

Cell_Base: 2000F

Electrical

Capacitance [NOM/MAX]: 55/58

Voltage: 97.2

DC ESR 10ms (mΩ) [Nom/Max]: 7.2/10.1

IEC DC ESR (mΩ) [Nom/Max]: 9.7/12.6

AC ESR (mΩ 1kHz) [Nom/Max]: 6.1/7.9

Hi Pot Test Voltage: 5000

UL Max Operational Voltage (per UL810A): 2000

Cycling (Calculated Values)

Continuous Current (A): TBD

Current Short Circuit (A): 13500

Current, Peak [1s] (A): 1900

Thermal (Reference)

Operational Storage Range: -40 to 85 °C

Resistance_Thermal (°C/W) [RTH]: TBD

Energy (Reference / Calculated using nominal values)

Emax (Whr) [Min/Nom]: 72.9/76.5

Height (mm): 224

Width (mm): 147

Length (mm): 690

Mass (kg): 28

Volume (L): 23

Terminal Fastener Size / Max Torque: M8/20Nm & M10/30Nm

Life (EOL Criteria) [CAP/ESR]

DC (10 Yr, 25°C, @VR): >44/<25

Endurance (2000hr, 85°C, @VR): >44/<25

Storage (2 yr, 70°C, @ 0V) >180/<4: >48/<18

Cycle (1M Cyc, 25°C, @ VR-VR/2): >44/<25

View Our Modules

For additional information, please contact the sales department by writing to xseries@ioxus.com

©2019 IOXUS Inc | 18 Stadium Circle, Oneonta, NY 13820 • 877-751-4222 • 607-441-3500